TeraAquaThemost innovative
heat pump of its kind.
TeraAqua
large heat pump
Highest performance
Maximum service life
High-tech software
The brine/water large heat pump
Experience the highest performance efficiency with minimal propane refrigerant. The TeraAqua brine-to-water heat pump uses stable, high-energy geothermal energy year-round to treat your heating and domestic hot water. For consistency, as well as energy and cost efficiency.
Thanks to propane refrigerant, the TeraAqua is characterized by effortless planning, installation and flexible integration. The dimensions and quantity of the refrigerant allow space-saving indoor placement without additional safety devices.
The most comprehensive range of propane services in the world.
Highest power efficiency from 80 to 1100 kW
Quality like a Swiss watch - Made in Germany.
Performance spectrum of TeraAqua large heat pumps
Technical data of the TeraAqua 80 kW
General data
Item number
TeraAqua80
B0/W35
- Min. heating power: 19.6 kW
- Max. Heating power: 81.4 kW
- COP: 4.94
B0/W55
- Min. heating power: 16.4 kW
- Max. Heating power: 68.0 kW
- COP: 3.35
Site
Indoor & outdoor
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +35° C
Heating water flow/return
16° to 70° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
39.6 A
Max. Absorbed power
23.7 kW
Sound
Sound power level ErP
<55 dB(A)
Dimensions
Device dimensions W/D/H
1700 x 1100 x 1798 mm
Total weight
1152 kg
Connection source
1 1/2" A.G.
Connection heating
1 1/2" A.G.
Connection ventilation
100 mm
Refrigerant
Propane R290
Refrigerant quantity
2.15 kg
CO2 Equivalence
6.30
Technical data of the TeraAqua 100 kW
General data
Item number
TeraAqua100
B0/W35
- Min. heating power: 26.8 kW
- Max. Heating power: 111.0 kW
- COP: 4.94
B0/W55
- Min. heating power: 22.3 kW
- Max. Heating power: 92.6 kW
- COP: 3.36
Site
Indoor & outdoor
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +35° C
Heating water flow/return
16° to 70° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
58.5 A
Max. Absorbed power
33.4 kW
Sound
Sound power level ErP
<55 dB(A)
Dimensions
Device dimensions W/D/H
1700 x 1100 x 1798 mm
Total weight
1174 kg
Connection source
1 1/2" A.G.
Connection heating
1 1/2" A.G.
Connection ventilation
100 mm
Refrigerant
Propane R290
Refrigerant quantity
2.65 kg
CO2 Equivalence
7.95
Technical data of the TeraAqua 150 kW
General data
Item number
TeraAqua150
B0/W35
- Min. heating power: 41.3 kW
- Max. Heating power: 149.0 kW
- COP: 4.85
B0/W55
- Min. heating power: 35.0 kW
- Max. Heating power: 126.0 kW
- COP: 3.16
Site
Indoor & outdoor
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +35° C
Heating water flow/return
16° to 70° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
86.9 A
Max. Absorbed power
50.9 kW
Sound
Sound power level ErP
<55 dB(A)
Dimensions
Device dimensions W/D/H
2000 x 1100 x 1798 mm
Total weight
1170 kg
Connection source
2 1/2" A.G.
Connection heating
2 1/2" A.G.
Connection ventilation
100 mm
Refrigerant
Propane R290
Refrigerant quantity
2.95 kg
CO2 Equivalence
8.85
Technical data of the TeraAqua 200 kW
General data
Item number
TeraAqua200
B0/W35
- Min. heat output: 57.6 kW
- Max. Heating output: 207.0 kW
- COP: 4.8
B0/W55
- Min. heat output: 48.9 kW
- Max. Heating output: 176.0 kW
- COP: 3.17
Site
Indoor & outdoor
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +35° C
Heating water flow/return
16° to 70° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
162.2 A
Max. Absorbed power
94.1 kW
Sound
Sound power level ErP
<55 dB(A)
Dimensions
Device dimensions W/D/H
2200 x 1200 x 1798 mm
Total weight
1588 kg
Connection source
3" A.G.
Connection heating
3" A.G.
Connection ventilation
100 mm
Refrigerant
Propane R290
Refrigerant quantity
4.35 kg
CO2 Equivalence
13.05
Technical data of the TeraAqua 280 kW
General data
Item number
TeraAqua280
B0/W35
- Min. heating power: 77.1 kW
- Max. Heating power: 277.0 kW
- COP: 4.83
B0/W55
- Min. heating power: 65.3 kW
- Max. Heating power: 235.0 kW
- COP: 3.17
Site
Indoor & outdoor
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +35° C
Heating water flow/return
16° to 70° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
162.2 A
Max. Absorbed power
94.1 kW
Sound
Sound power level ErP
<55 dB(A)
Dimensions
Device dimensions W/D/H
2200 x 1200 x 1798 mm
Total weight
1627 kg
Connection source
3" A.G.
Connection heating
3" A.G.
Connection ventilation
100 mm
Refrigerant
Propane R290
Refrigerant quantity
4.85 kg
CO2 Equivalence
14.55
Technical data of the TeraAqua 550 kW
General data
Item number
TeraAqua550
B0/W35
- Min. heating power: 279.0 kW
- Max. Heating power: 558.0 kW
- COP: 4.82
B0/W55
- Min. heating power: 240.0 kW
- Max. Heating power: 481.0 kW
- COP: 3.01
Site
outdoors
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +25° C
Heating water flow/return
16° to 52° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
330.0 A
Max. Absorbed power
160.0 kW
Sound
Sound power level ErP
<68 dB(A)
Dimensions
Device dimensions W/D/H
4700 x 2300 x 2700 mm
Total weight
3600 kg
Connection source
4" A.G.
Connection heating
4" A.G.
Connection ventilation
120 mm
Refrigerant
Propane R290
Refrigerant quantity
26.3 kg
CO2 Equivalence
78.9
Technical data of the TeraAqua 1100 kW
General data
Item number
TeraAqua1100
B0/W35
- Min. heating power: 566.0 kW
- Max. Heating power: 1133.0 kW
- COP: 4.72
B0/W55
- Min. heating power: 500.0 kW
- Max. Heating power: 998.0 kW
- COP: 3.05
Site
outdoors
Quantity compressors
1
Number of circulating pumps
-
Periphery
Pumps source and sink
Connection & regulation
Mixing valves source and sink
Connection & regulation
Frost protection device
Available
Pressure drop circuits
max. 60 kPa
RegliControl Logic regulation
- Stand alone
- Modbus RTU, BacNet
- Hardware signals
- Heating controller and more.
Application limits
Brine (concentration up to 40% ethylene glycol)
-20° to +25° C
Heating water flow/return
16° to 52° C
Min. buffer storage volume
-
Electrical connection
Power current
3x400VAC/50Hz
Control current
230VAC / 24VDC
Starting current limiter
Inverter
Protection class
IP 62
Max. Current consumption
566.0 A
Max. Absorbed power
332.0 kW
Sound
Sound power level ErP
<68 dB(A)
Dimensions
Device dimensions W/D/H
5100 x 2400 x 2700 mm
Total weight
4600 kg
Connection source
5" A.G.
Connection heating
5" A.G.
Connection ventilation
120 mm
Refrigerant
Propane R290
Refrigerant quantity
53.0 kg
CO2 Equivalence
159.0
Areas of application for TeraAqua large heat pumps
Multi-family housesClimate-neutralheating for houses with more than 7 parties
When the installation of cascaded heat pumps becomes expensive, our TeraAqua machines offer an economical alternative. A single system supplies all apartments with heating and domestic hot water, even with multiple demands - so you save massively on heating costs.
Benefit from our experience in dealing with heating replacement in apartment buildings.
Office buildingSustainableheating system for a pleasant office climate
A pleasant room temperature promotes not only comfort but also the ability to concentrate. Buildings with a large number of offices should therefore be equipped with both heating and cooling.
The heat pump technology of the TeraAqua makes both functions possible from one system - so you save on purchase and use.